The 1586A Super-DAQ collects time-stamped precision temperature and electrical measurements for data analysis by technicians, engineers, and quality control personnel to verify process control, analyze interactive systems, ensure conformance to quality standards, or to correlate related events for R&D or troubleshooting. Measurement data and statistics can be viewed in tabular format for all active channels. With the graphing feature, up to four channels can be plotted at the same time, making it easy to quickly assess test setup and results before analyzing the data on a PC.

When configured with the DAQ-STAQ Multiplexer, the Super-DAQ has the accuracy of the best benchtop reference thermometer readouts for calibration of PRTs, RTDs, thermistors, or thermocouples. Lab efficiency can be increased when the Super-DAQ is connected to a Fluke Calibration drywell or bath and Automated Sensor Test routines are run.

The 1586 is ideal for a number of applications such as thermal mapping, temperature validation, process sensor calibration, and more. These applications are found in a various industries including pharmaceutical, biotechnology, food processing, aerospace, and automotive.

Some temperature data acquisition applications require compliance to government and standards agency requirements. TQSoft and TQAero thermal validation software help engineers, technicians and lab managers to meet the key guidelines for temperature data collection. These software solutions provide a complete qualification, reporting, documentation, and audit trail management system.

There are six key features that set the Super-DAQ apart from other products in its class:

  1. Best temperature measurement accuracy
  2. Flexible configuration for the factory or benchtop
  3. Multiple modes of operation
  4. Real-time graphing in color
  5. Data portability and security
  6. Automated sensor calibration

1. Best temperature measurement accuracy

The 1586A Super-DAQ reads PRTs, thermocouples, and thermistors with best-in-class accuracy:

  • PRTs ± 0.005 °C (using external DAQ-STAQ Multiplexer)
  • Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
  • Thermistors: ± 0.002 °C

2. Flexible configuration for the factory or benchtop

For factory applications, the Super-DAQ is configured with the internal High-Capacity Module. Connecting thermocouples or RTDs to input terminals can be time consuming—especially if you're using many sensors of the same type for one job, and then switching to a different sensor type for another job. The internal High-Capacity Module allows you to pre-configure multiple input modules and simply exchange one module for another, depending on your test requirements. Recall a stored test setup to make the changeover even faster. And if you prefer, you can always measure a variety of different input types at the same time in a single High-Capacity Module, including thermocouples, RTDs, voltage, resistance, or current.

For a calibration lab where accuracy is of primary importance, the Super-DAQ is best configured with a DAQ-STAQ Multiplexer. The external DAQ-STAQ features mini-jack thermocouple terminals—each with its own reference junction sensor—and patented mini-DWF, gold-plated input terminals, which accept bare wire, spade lug, or mini-banana-plug terminations. Easily connect and disconnect PRTs, thermistors, and thermocouples for benchtop temperature calibration. It can be stacked on the 1586 to reduce footprint in busy labs. Flexibility to configure the Super-DAQ for factory or calibration lab use reduces your equipment needs and cost.

3. Multiple modes of operation

The Super-DAQ can operate in four modes that let you scan, monitor, measure, or function as a digital multimeter from a single instrument. Sequentially scan through channels based on a user defined test. Monitor any single channel during a scan, without interrupting the scan. Measure and record data on a single channel without the need of a pre-configured test file. Or in DMM mode, use the front panel channel like a familiar benchtop digital multimeter to quickly measure dc voltage, dc current, or 2-wire and 4-wire resistance without the need to configure the channel.

4. Real-time graphing in color

Most data acquisition systems only let you view data on one channel. But now the Super-DAQ, lets you view real time data for all channels in table format, or you can chart up to four channels in color at the same time. You can zoom in or out to see data of interest and monitor trends. A history mode lets you scroll through collected data within a scan file—all without a PC and expensive charting programs. Switch between chart view and table view of various measurement data and statistics

5. Data portability and security

The Super-DAQ includes 20 MB internal memory that can store over 75,000 time-stamped readings. Data and set-up files can be easily moved to a PC for analysis using a USB flash drive or over a network using the LAN interface connection. The Super-DAQ also includes two levels of data security to prevent unauthorized users from tampering with or forging test data or setup files. This security feature is especially important to industries that are regulated by government agencies where data traceability is required.

6. Automated sensor calibration

With the Automated Test feature, you can automate sensor calibration without a PC and software. When connected to a Fluke Calibration drywell or fluid bath via the RS-232 interface, the Super-DAQ takes control of the temperature source and runs your calibration automatically. You simply program the number of setpoint temperatures and their values, select a scan sequence (linear, alternate, up/down), assign a reference channel, and set the required stability band. The Super-DAQ monitors the temperature source's stability via the reference channel, collects the data once stabilized, and then advances to the next setpoint temperature. After you configure and start the test, you can walk away to work on other things. The Super-DAQ just made your day a whole lot easier.

One temperature source can be connected to the Super-DAQ at a time. The Super-DAQ can control all of the following Fluke Calibration models:

  • Field Metrology Wells: 9142, 9143, 9144, 9190A
  • Portable Calibration Baths: 6109A, 7109A
  • Metrology Wells: 9170, 9171, 9172, 9173
  • Handheld Calibrators: 9100S, 9102S
  • Field Dry-Well Calibrators: 3125, 9009, 9103, 9140, 9141
  • Thermocouple Furnace: 9150, 9118A
  • Dual Block Dry-Well: 9011
  • Micro Baths: 6102, 7102, 7103
  • Compact Baths: 6330, 7320, 7340, 7380
  • Deep-Well Compact Baths: 6331, 7321, 7341, 7381
  • Triple Point of Water Maintenance Bath: 7312
  • High Temperature Oil Baths: 6020, 6022, 6024
  • High Temperature Salt Bath: 6050H
  • Cold Temperature Baths: 7008, 7040, 7037, 7012, 7060, 7080
  • Deep-Well Baths: 6054, 6055, 7007
  • Resistor Baths: 7009, 7108, 7015
Model Name Description
1586A/1DS

Super-DAQ Precision Temperature Scanner, 1 DAQ-STAQ Multiplexer

1586A/1DS/C

Super-DAQ Precision Temperature Scanner, 1 DAQ-STAQ Multiplexer, Accredited Calibration

1586A/2DS

Super-DAQ Precision Temperature Scanner, 2 DAQ-STAQ Multiplexers

1586A/2DS/C

Super-DAQ Precision Temperature Scanner, 2 DAQ-STAQ Multiplexers, Accredited Calibration

1586A/DS-HC

Super-DAQ Precision Temperature Scanner, 1 High-Capacity Module, 1 DAQ-STAQ Multiplexer

1586A/DSHC/C

Super-DAQ Precision Temperature Scanner, 1 High-Capacity Module, 1 DAQ-STAQ Multiplexer, Accredited Calibration

1586A/1HC

Super-DAQ Precision Temperature Scanner, 1 High-Capacity Module

1586A/1HC/C

Super-DAQ Precision Temperature Scanner, 1 HIgh-Capacity Module, Accredited Calibration

1586A/2HC

Super-DAQ Precision Temperature Scanner, 2 High-Capacity Modules

1586A/2HC/C

Super-DAQ Precision Temperature Scanner, 2 High-Capacity Modules, Accredited Calibration

2680A-APSW v6.0

Fluke DAQ 6.0 Application Software for Fluke data acquisition products.
Click here for more information »

TQSOFT-IQ/OQ

TQSoft Pharma Process Analysis and Validation Software

TQAERO

TQAero Furnace Validation Software

VAL-BNDR-TQS

Validation Reference Binder

Accessories common to all models:

Accessory Description
1586-2586

High-Capacity Module without Relay Card

1586-2586/C

High-Capacity Module without Relay Card, Accredited Calibration

1586-2586-KIT

High-Capacity Module with Relay Card

1586-2586-KIT/C

High-Capacity Module with Relay Card, Accredited Calibration

1586-2588

DAQ-STAQ Multiplexer without Adapter Card

1586-2588/C

DAQ-STAQ Multiplexer without Adapter Card, Accredited Calibration

1586-2588-KIT

DAQ-STAQ Mutiplexer, Adapter Card, Interface Cable

1586-2588-KIT/C

DAQ-STAQ Multiplexer, Adapter Card, Interface Cable, Accredited Calibration

1586-2588-CBL

DAQ-STAQ Multiplexer Interface Cable

1586A-101

10-ohm Current Shunt Resistors, set of 10

Y1586S

Rack Mount Kit, Single (half rack)

Y1586D

Rack Mount Kit, Dual (full rack)

1586-CASE

Carrying Case for 1586A Super-DAQ

1586/DS-CASE

Super-DAQ/DAQ-STAQ Carrying Case (mainframe and external module)

1586A Super-DAQ Precision Temperature Scanner (2024)
Top Articles
Latest Posts
Article information

Author: Sen. Emmett Berge

Last Updated:

Views: 6470

Rating: 5 / 5 (60 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Sen. Emmett Berge

Birthday: 1993-06-17

Address: 787 Elvis Divide, Port Brice, OH 24507-6802

Phone: +9779049645255

Job: Senior Healthcare Specialist

Hobby: Cycling, Model building, Kitesurfing, Origami, Lapidary, Dance, Basketball

Introduction: My name is Sen. Emmett Berge, I am a funny, vast, charming, courageous, enthusiastic, jolly, famous person who loves writing and wants to share my knowledge and understanding with you.